Electrical switchboard switchgear testing and commissioning. Standard for acceptance testing specifications for. Maintenance of electrical switchgear ms28, tl4 11 chapter 1 introduction 110 purpose 111 scope this handbook contains information on safety practices and environmental considerations when working on switchgear, descriptions of typical classes of switchgear, and preventive and corrective maintenance guidelines for switchgear. An eaton 515 kv type vaccladw metalclad switchgear indoor housing assembly.
Type and routine tests general kinds, valid for all switchgear and controlgear. Medium voltage operation mv drives and soft starters are temporarily installed in the mv test bay and operated on an mv dynamometer. A detailed description of construction requirements. General descriptions of the operation and maintenance of the powlvac metalclad switchgear 3. Ms28 handbook maintenance of electrical switchgear tl4. Testing and commissioning requirements for switchgear. Pdf mv switchgear components inspection and test procedure find, read and cite all the research you need on. The current method of testing circuit breakers 05152011one of the most critical devices on any electricity network is the circuit breaker which can be described as the silent sentinel, standing guard over the network and only being called into action when. Medium voltage switchgear ax1 is described in many different publications and even in a. Netas 2010 outstanding acheievement award honoring netas most valuable asset.
Repeat for poles 2 through 6, in turn, with other poles grounded. Ac power frequency overvoltage test to ascertain suitability of plant for energisation. Insulation resistance, ac hipot, dc hipot, low resistance test. Switchgear and circuit breakers failures and case studies ue systems 2015 reliable asset conference june 4th. Testing manual for electrical equipment requirements are fulfilled. Dielectric test on the main circuit iec 62271102 7. Applying voltage to the equipment and connecting to a test motor in the mv test. Instructions for installation, operation, and maintenance. Mv clad switch gear instalaltion and testing procedure. It is necessary that all testing tools are available before starting the work. Switchgear solutions for primary and secondary distribution to suit every application. Manual installation commissioning environment and recycling.
For medium voltage switchgear and controlgear the r. Gasinsulated switchgear factory acceptance test and remote factory acceptance test. This standard provides information essential to designing and testing of metalclad switchgear. A small handheld control console allows the user to fully monitor and control all the switchgear testing process. Switchgear testing and commissioning procedure busbar torque test. The following sections of the ansineta standard for acceptance testing specifications for. Therefore at least following tools shall be arranged before starting the electrical testing job. Thoroughly test the switchgear at the factory with the circuit breakers in the connected. For the testing earthed circuit, the connection to the earth shall be removed before the test. Factory acceptance tests fat the routine tests shall be made with each electrical equipment and, whenever practicable. Disconnect all low voltage and medium voltage power sources to the switchgear assembly before working on the equipment per the occupational safety and health act osha and lockout procedures.
Typical factory test procedures for medium voltage products. Guides and standards for circuit breakers, switchgear, relays. Included herein are preferred ratings, required design test procedures, and acceptance criteria. Green berets ultralight bug out bag with gear recommendations duration. Tests shall be conducted as per ul, ansi and csa standards. Pdf mv switchgear circuit breaker inspection and test procedure find, read and cite all the research you need on researchgate. Medium voltage switchgear shall be thoroughly tested at the factory to assure that there are no electrical or mechanical defects.
Instructions for installation and placing the switchgear into service 4. Pdf format or scanned version have the status for information only. Switchgear and switchboard inspection and testing guide. Procedure h r a 7 switchgear mechanical operation test procedure iec, nec, nema, fdf, iso ansi, ci, ipcea iec, nec, nema, fdf, iso ansi, ci, ipcea procedure h r a inspection and test plan for switchgear before manufacturing materials activity by no. Substations and switchgear in an electrical system perform the functions of voltage transformation, system protection, power factor correction metering, and circuit switching. Most importantly all measuring tools must have valid calibration certificate at the. Laboratory testing of internal development and type test. The most important tests for medium voltage metalenclosed. Visual and mechanical inspection a equipment nameplate data shall be documented. The test procedure described are applicable to metal clad switchboards.
Thoroughly test the switchgear at the factory with the circuit breakers in the connected position in their cubicles. Dc overvoltage test to ascertain suitability of plant for energisation. This guide direction is prepared for related stages to the pre commissioning and commissioning of switchgear. Safety operations on medium voltage switchgear author and presenter. Inspection, testing and commissioning of electrical. Inspection and test plan reference document acceptance criteria verifying document 1. Inspection, test and measurement procedures for lv and mv. Pdf mv switchgear inspection and test procedure find, read and cite all the research you need on researchgate.
Connec t all low voltage w ires together and appl y the test voltag e between the w ires and ground. For switchgear with proven internal arc classification according to iec 62271 part 200, no protective equipment is required for operating the switchgear. Switchgear, transformers, cables, overhead lines, surge arresters, voltage transformers, current transformers, unit substations. The complete guide to electrical insulation testing. To work on switchgear where covers have to be removed, personal protective equipment has to be worn for protection against hot gases exhausting in case of internal arc. For all customers, from system integrators to end users, and all applications, from refurbishment, line extension to new installations. In this article i go to share the actual what we do in after panel switchgear installation and what are the procedure of switchgear testing and commissioning. For example, a small pump motor or a short control cable may be vital to a process in your plant. The test shall demonstrate that the replacement of the meter does not require the switching off of the respective switchgear. Mv and lv switchgear test procedure simpprime, sivacon the aim of this document is description of the responsibilities of the test procedure during all stages related to switch board.
In sulation resis t an ce test of a ll low v olta ge wi ring a nd cabling a t 500 v dc. The simosec medium voltage metalenclosed switchgear is designed to meet all the applicable ansi, nema and ieee standards, or the applicable iec. Isolation procedure the authorised person shall carry out the necessary isolations, using personal locks, according. Instructions for installation, operation, and maintenance of 5. The incredibly small size and weight of the raptor system allows the portability required for switchgear testing, being possible to place the test set closer to the switchgear panel or to breaker, and reduce the power required. All material can be ordered from abb kraft ab on telephone int. This assures complete interoperability, which has been tested. Electrical power aparatus, such as transformers, regulators, air switches, circuit breakers, capacitors. The international electrical testing association neta was formed in 1972 to establish uniform testing procedures for electrical equipment and apparatus. Connect hv lead to pole 1 or 2, as convenient, with either pole of phase 2 and 3 grounded. Typical factory test procedures for medium voltage products 3. Switchgear and circuit breaker failure beyond the loss of the cbs and switchgear.
Whether you test monthly, twice a year, or once a year depends upon the type, location, and importance of the equipment. Efacec is a leading company in portugal and a worldwide reference in the development of solutions for power generation, transmission, distribution and use of electrical energy in the. Medium voltage switchgear ax1 is described in many different publications and even in a multimedia presentation on cdrom. Measurement of the resistance of the main circuit iec 62271102 7. When testing medium voltage the three point test should be adopted, test the tester. Medium voltagelow voltage mvlv transformer substations 1.
Neta developed specifications for the acceptance of new electrical apparatus prior to energization and for the maintenance of existing apparatus to determine its suitability to remain in service. Medium voltage and low voltage switchgear test procedure. Inspection, test and measurement procedures for lv and mv up to 36kv switchgears on photo eaton cutler hammer magnum ds switchgear inspection, and transformer testing for mv switchgear similar considerations apply although more extensive checks on protective devices, circuit breaker oil, vacuum bottle contact distances are required as specified by the manufacturer. All electrical and mechanical operating procedures take place when the enclosure doors are closed. Medium voltage distribution pix schneider electric. Interview crews about problems they may have encountered. The contents of this manual follow the procedures for working with ax1.
Section 7 of the ansineta standard for acceptance testing specifications for electrical power equipment and systems may be reproduced and used on a cut and paste basis for the particular type of equipment to be tested. Inspection, test and measurement procedures for lv and mv up to 36kv switchgears on photo eaton cutler hammer magnum ds switchgear inspection, and transformer testing for mv switchgear similar considerations apply although more extensive checks on protective devices, circuit breaker oil, vacuum bottle contact distances are required as. Electrical switchboard switchgear testing and commissioning manual from 3. Remove grounds and then test to ensure you have no unintentional grounds. After the insulation resistance test, voltage withstand tests for main circuit and control circuit shall be carried out, and no electrical or mechanical defects shall be found. Disconnect all low voltage and medium voltage power sources. Medium voltage switchgear construction checklist page 5 of 6 version 0206 electrically operated circuit breakers exercised in manual mode electrically operated in test position and fully engaged position without main bus voltage applied all incoming cables are terminated and abc phasing is correct. You can find below a comprehensive switchgear testing and commissioning procedure.